Product Name | 3 in 1 Forehead & Ear Temperature Thermometer AOJ-20H |
Applicable Regulations and laws | ASTM E-1965-98(Reapproved 2009) standard specification for Infrared thermometers for intermittent determination of patient temperature ISO80601-2-56 first edition 2009-10-01 medical electrical equipment -part 2-56: particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement. (general plastic surgery/general hospital) |
Display | Segment LCD display, 4 colors LED backlight |
Temperature Units | °C/°F, Switchable |
Power Supply | DC 3V, AAA*2 |
Measurement Range | Forehead: 32°C-42.9°C(89.6°F-109.2°F) Ear: 32°C-42.9°C(89.6°F-109.2°F) Object: 0°C-100°C(32°F-199°F) |
Accuracy(Laboratory) | Ear&Forehead mode ±0.2°C/±0.4°F Object mode ±1°C/±2°F |
Display Resolution | 0.1°C/°F |
Automatic Shut Down | 10s±1s |
Memory | 40 Groups of values |
Operational Conditions | Temperature:10°C-40°C (50°F-104°F)/Humidity:15%-95%RH,non-condensing atmospheric pressure:70-106kPa |
Storage Condition | Ambient temperature:20°C-55°C(-4°F-131°F)relative humidity: 0-95% RH,non-condensing atmospheric pressure:50Kpa to 106Kpa |
Battery | 2*aaa can be used for more than 3000 times temperature measurement |
Gross Weight&Dimension | 93g(with Batteries)163.5*40*41mm |
Product name |
FDA-approved 510k non-contact infrared thermometer with local medical device license |
|
Applicable regulations and laws
|
ASTM E 1965-98 (Reapproved 2009) Standard Specification for Infrared Thermometers for Intermittent Determination of Patient Temperature |
|
ISO80601-2-56 First Edition 2009-10-01 Medical Electrical Equipment - Part 2-56: Particular Requirements For Basic Safety And Essential Performance Of Clinical Thermometers For Body Temperature Measurement. (General Plastic Surgery/General Hospital) |
||
Display |
Segment LCD, green and red LCD backlight |
|
Temperature units |
℃ /℉, switchable |
|
Power supply |
DC 3V, AAAX2 |
|
Measurement range |
Forehead: 32.0°C-42.9°C (98.6°F-109.2°F) |
|
Ear: 32.0°C-42.9°C (98.6°F-109.2°F) |
||
Object: 0°C-100°C (32°F-212°F) |
||
Accuracy (Laboratory) |
Ear & Forehead mode |
±0.2℃ /±0.4℉ |
Object mode |
±1.0°C/2.0°F |
|
Display resolution |
0.1℃/℉ |
|
Automatic shutdown |
10s±1s |
|
Memory |
40 groups of the measured temperature. |
|
Operational conditions |
Temperature: 10℃-40℃ (50℉-104℉) / Humidity: 15-95%RH, non-condensing Atmospheric pressure: 70-106 kPa |
|
Storage condition |
Ambient Temperature: -20°C to 55°C (-4°F-131°F) Relative Humidity: 0-95% RH, non-condensing Atmospheric pressure: 50kPa to 106kPa |
|
Battery |
2*AAA can be used more than 3000 times |
|
Weight & Dimension |
80g (with battery), 143×35×41mm(body size) |